| FEATURES |
| Continuous log of fluid properties. |
| Measurement in-situ reduces sample storage |
| requirements and contamination |
| MEASUREMENTS |
| Temperature |
| Pressure |
| Fluid conductivity |
| Oxygen(ppm) |
| pH |
| Redox potential |
| Derived: |
| Differential temperature |
| Fluid resistivity |
| Oxygen saturation |
| APPLICATIONS |
| Water |
Water-quality measurements
Location of aquifers
Groundwater flows
Contamination studies |
| OPERATING
CONDITIONS |
| Borehole type |
Open/cased hole, water-filled
In normal logging operations, the borehole should be allowed to stand for 24
hours to reach stable conditions and this probe should be run first. The log
is recorded downwards while running into the hole to minimise fluid disturbance. |
| SPECIFICATIONS |
| Diameter |
43mm |
| Length |
1.66m |
| Max. temperature |
70ºC |
| Max. pressure |
15MPa |
| Response time constant |
50ms (temperature, pressure, conductivity),
3s (others) |
| Pressure measurement |
Range:0 to 1500dbar,
Accuracy: 0.25% full scale |
| Temperature measurement |
Range: -1 to 49ºC (extended
ranges available)
Accuracy: 0.02ºC |
| Conductivity measurement |
Range: 0 to 62mS/cm,
Accuracy: 0.02mS/cm |
| Dissolved-oxygen measurement |
Range: 0 to 50ppm,
Accuracy: 0.1ppm |
| pH measurement |
Range: 0 to 14pH,
Accuracy: 0.01pH |
| Redox measurement |
Range: -1000 to 1000mV,
Accuracy: 10mV |
| SALES INFORMATION |
| Probe |
| 25 051 001 |
Water-quality probe with temperature
and pressure sensors |
| 24 051 003 |
Conductivity sensor |
| 25 051 004 |
Dissolved-oxygen sensor |
| 25 051 005 |
pH sensor |
| 25 051 006 |
Redox sensor |
| 25 051 007 |
Iodine sensor |
| 25 051 008 |
Copper sensor |