FEATURES:
|
| Small diameter for slim-hole operations |
| Extension arms available for small diameter
probe |
| Optional natural-gamma measurement |
|
MEASUREMENTS:
|
| Caliper |
| Natural Gamma (optional) |
| Casing collar locator
CCL (optional) Borehole volume |
|
APPLICATIONS:
|
|
Engineering/Minerals
Water:
|
Location of borehole collapse or obstructions
Cement volume calculations for grouting
Identification of hard and soft lithology
Location of cracks, fissures, caving, faulting, casing
breaks
Correction of other logs affected by borehole diameter
|
|
OPERATING CONDITIONS:
|
|
Borehole type:
|
open/ cased; water/air-filled
|
|
Centralisation:
|
recommended in large holes
|
|
SPECIFICATIONS:
|
|
Standard three-arm caliper probe
|
|
Diameter:
|
38mm
|
|
Length:
|
2.13m (two sections)
|
|
Weight:
|
9.2kg
|
|
Range:
|
40-300mm (710mm with extension arms)
|
|
|
|
|
Long-arm caliper probe
|
|
|
Diameter:
|
60mm
|
|
Length:
|
2.50m
|
|
Weight:
|
13kg
|
|
Range:
|
65-1000mm
|
|
Max. temperature:
|
70ºC (extended range available)
|
|
Max. pressure:
|
20MPa (extended range available)
|
|
Accuracy:
|
+/- 6mm
|
|
Natural-gamma detector:
|
50mm x 25mm NaI(Tl) scintillation crystal
(larger sizes available)
|
|
SALES INFORMATION:
|
|
Probe:
|
|
|
25 030 000
|
Standard caliper probe with arm extension
kit and calibrator
|
|
25 031 000
|
including natural gamma
|
|
25 033 000
|
Long-arm caliper probe with calibrator
|
|
25 034 000
|
including natural gamma
|
|
25 032 000
|
including casing-collar locator (CCL)
|
| |
|
|
Accessories:
|
|
|
21 001 000
|
Centraliser 90 - 180mm
|
|
21 002 000
|
Centraliser 180 - 260mm
|
|
21 003 000
|
Centraliser 260 - 342mm
|
|
21 004 000
|
Centraliser 342 - 472mm
|
|
20 070 000
|
Natural-gamma API calibrator without source
|
|
30 010 000
|
3.7MBq 137Cs source for natural gamma
calibrator
|